Dr.Sherlock Graph
TEMPERATURE ALARM
Easy operation
- Right turnable button provides easy access to the menus
- Left turnable button is used to select which input changes apply to etc.
- Alarm condition is provided in meaningful text
- Logical structure and self explanatory interface making a manual more or less superfluous
- Speech processor commands are shown and can be changed directly
User settings
- Input names can be changed. Changes are automatically transferred to the speech computer
- Each input can be set as either a temperature input or ON/OFF input
Perfect survey
- Temperatures and status for each input are show in the display
-
Everything can be set directly from the panel - no external adjustment are
needed
Alarms
- High and low absolute temperature alarm limits
- High and low relative
temperature alarm limits compared to a "normal temperature" measured between
6 and 7 in the morning
- In addition to lightning/transient protection
short (insignificant) alarms are filtered
Selective alarm handling
Alarm handling can be set for each input as needed:
- - both siren and alarm dialup.
- - siren only
- - only during daytime hours
- - as beep only and on request only (soft alarm)
Heat wave compensation
- In order to avoid unwanted alarms on a warm summer day (heat wave), it is possible to specify a parameter in °C
by which the indoor temperature is allowed to rise above the outdoor temperature. This can be done separately for each input.
Safety
- Alarm for defects - short circuits and broken cables - at all inputs.
- Alarm at too low voltage in power supply.
- Temperature sensors and keyboard housing are IP 65.
- Possibility for automatic test of accumulator every day at 0800 hrs.
Graphical survey
Clear and easy graphical survey with:
- Temperature trends shown as curves
- High and low values
- Alarm condition
Speech Processor
- A Speech Processor Dr.Bell performs alarm dialup and informs in clear speech.
- Remote control - setting parameters using a telephone.
Communication
RS485 interface is integrated. Communication opens up
possibilities which you will soon appreciate.
- Communication with a PC and Professor Partyline for presentation of
trends of the temperature. Remote control - for example setting of alarm limits and toggle
active/idle mode of each input. This can also be done through telephone by means of a modem.
- By means of a Speech Processor Dr.Bell inquiries and operation can also be done through
telephone.
Expansion Possibilities
- Can be expanded by more units connected in network.
- Supervision of O2 and pH-value and other parameters on request.
|
© 1998- Klima Design A/S - controllers climate computers actuators alarm systems
|